Boiler Hydrotest and preservation SOP docx - OPG POWER
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Jul 19, 2018 · Boiler is kept under pressure, so that atmospheric air can't enter in to Boiler pressure parts. Procedure of wet Preservation The boiler should be filled with feedwater to the normal water level then 90% water level of gauge glass. Maintain ph up to 9.5-11. Hydrazine 200 PPM is to be dosesed with the water. Ensure uniform concentration.Get Price
Aug 30, 2017 · Boiler Hydrostatic testing pressure gauge. If no leakage is observed to the satisfaction of the inspecting personnel, start the pressurizing pump. Raise the pressure gradually to 25% of the hydro test pressure and repeat the above steps. Similarly do it for 50% and 75% of the hydro test pressure.Get Price
Boiler Preservation Methods Dry and Wet - BoilersinfoGet Price
Boiler Hydrotest and preservation SOP.docx. 4 pages. Boiler forced cooling.xlsx Vels University MECHANICAL 123 - Fall 2020 Register Now Boiler forced cooling.xlsx. 1 pages. 1.png OPG_Technical_Diary.docx Vels University MECHANICAL 123 - Fall 2020 Get Price
Boiler Preservation Methods Dry and Wet - BoilersinfoGet Price
OPG POWER GENERATION PVT LTD., 1X180 MW THERMAL POWER PLANT DOC NO: OPGPG/2/OPN/BLR/01/11 DOC TITLE SOP OF BOILER HYTRO TEST & PRESERVATION REV NO 0 DATE 10-APRIL-20 Hydrostatic pressure shall be boosted slowly.Get Price
SOP for Starting and Stopping of Boilers : Pharmaceutical Get Price
capacity also called power of a boiler. It is defined as the amount of water evaporated or steam produced in kg per hour. It may also be expressed in kg per kg of fuel burnt or kg/hr/m2 of heating surface. 2.1.1 Boiler Classifications Boilers are classified by …Get Price
Boiler – Fundamentals and Best PracticesGet Price
Raise pressure slowly to desired hydro test pressure. If no leak found then Raise pressure slowly to desired hydro test pressure with the help of portable hydro pump. Rate of. pressure increase must not exceed 50 psig (3.5 kg /cm2g) per …Get Price
OPG Power Ventures Plc boiler and auxiliary systems,control and monitoring the BTG parameter as per curve.Commissioning activities of BTG like boiler hydro-test,chemical cleaning,pre-boiler chemical cleaning,lube oil flushing,EH oil flushing,boiler steam blowing,turbine turning gear activities,boiler light-up activities,turbine tests,steam Get Price
The boiler room log lists boiler operation data that can be used to increase boiler safety and efficiency as well as identifying a potential malfunction. 8-A boiler room log is used to record information regarding operation of the boiler during a given period of time. The number and frequency of the checks to be performed depend on the plant.Get Price